logo
En casa. > productos > Equipo de prueba de la inflamabilidad >
Flammability Tester Fire Propagation Test Apparatus

Flammability Tester Fire Propagation Test Apparatus

flammability tester fire propagation

fire propagation test apparatus

flammability testing equipment with warranty

Lugar de origen:

China.

Nombre de la marca:

YUYANG

Certificación:

ASTM E84, UL723

Número de modelo:

En el caso de las empresas de servicios de seguros

Contacta con nosotros
Pida una cita
Detalles del producto
Nombre del producto:
Equipo de ensayo de inflamabilidad
Uso:
Prueba de características de quema de superficie
Fuerza:
220V 50Hz
TAMAÑO DEL HORNO DE PRUEBA:
L9456*W1067*H1400
soporte personalizado:
OEM, ODM
Manómetro:
0 ~ 200kpa (0 ~ 30psi)
Temperatura máxima de Firebrick:
2500℃
Presión:
86 ~ 106Kpa
Resaltar:

flammability tester fire propagation

,

fire propagation test apparatus

,

flammability testing equipment with warranty

Condiciones de pago y envío
Cantidad de orden mínima
1 set
Precio
negotiable
Detalles de empaquetado
Caja de madera contrachapada
Tiempo de entrega
35 días de trabajo
Condiciones de pago
T/T, L/C, Western Union
Capacidad de la fuente
3 sistemas por cuarto
Descripción del producto
Flammability Tester Fire Propagation Test Apparatus
Product Description

This apparatus is designed to determine surface burning characteristics of building materials and flame propagation rate of exposed surfaces such as walls and ceilings (including solid plastics), while simultaneously measuring smoke density.

Application

This test method applies to exposed surfaces including ceilings or walls, provided the materials or assemblies can support themselves or be supported during testing. The method determines burning behavior by observing flame spread along test specimens, with reports generated for flame spread and smoke density measurements.

Standards Compliance
  • ASTM E84: Standard test method for surface burning characteristics of building materials
  • UL723: Test for surface burning characteristics of building materials
Technical Parameters
  • Power: AC380V±10%
  • Max Power: 5KW
  • Test tunnel furnace: Length 7.62M, open end cross section 0.45M * 0.3M, firebrick max temperature 2500℃
  • Observation: 16 isometric observation windows, one fire observation window with double-layer high-temperature quartz glass, SUS304 stainless steel frame
  • Sealing: Water seal structure with sample cover plate sides broken into tank during test for better sealing
  • Air control: Adjustable shutter for precise air flow control inside furnace
  • Thermocouple: K-type, diameter 3mm, 3 sets (Omega USA imported), measuring range ≤1300℃
  • Exhaust port: Rectangle to round transition, diameter 406mm
  • Smoke density measurement: Installed 4.9~12.2M from tunnel furnace
  • Gas burner: Spaced 305mm from fire end, 190mm below test sample surface
  • Light source: Two gas burners, nozzle distance 203mm, energy output 5.3Mj/min
  • Ignition: High voltage electronic ignition
Component Specifications
  • Test furnace size: L9456*W1067*H1400 (excluding flue)
  • Furnace base: 100*50 channel steel welded, surface spray treatment
  • Flue: Double-layer with high temperature asbestos center, SUS304 stainless steel inner layer, galvanized sheet outer layer (T1.2)
  • Sample plate: Calcium silicate cement board, high temperature resistant to 1300℃
  • Sample cover: T2.0 SUS304 stainless steel
  • Control box: T1.2 cold plate, CNC formed, white painted surface
Gas Control System
  • Gas: 99% purity (supplied by user)
  • Flow meter: Domestic brand, range 2~20L/min, accuracy 2%
  • U type pressure gauge: USA origin, water column 0~36 inches, resolution 0.1 inch
  • Pressure gauge: 0~200Kpa (0~30psi), resolution 5Kpa
  • Pressure regulating valve: 0~10kg/min continuously adjustable
Smoke Density Measurement
  • Light source: Imported quartz halogen lamp (100W, 12V, 2000~3000Lm)
  • Receiver: Spectral response matches CIE light meter standards
  • Installation: Installed at pipe end (length 150), opposite end has dustproof window, glossy black anti-reflection inner wall
  • Light transmittance: 0% = no light, 100% = full transmission
Control System
  • Computer control system with PC and printer (Windows XP)
  • Light transmittance measurement software for curve and report generation
  • All electronic components from domestic leading brands
  • Safety protections: Power overload, short circuit protection, control circuit overload protection
Flammability Tester Fire Propagation Test Apparatus 0
Figure 1: Control system interface
Testing Features
  • Measures flame propagation speed based on time of flame through observation windows
  • Requires calibration and two preliminary tests (red oak and asbestos cement specimens)
  • Calculates Flame Spread Index (FSI) using specific formulas based on total area measurements
  • Materials classified: Class A (0-25), Class B (26-75), Class C (76-200)
  • High buildings require FSI<25 materials; FSI>100 materials don't meet flame retardant requirements
Testing Procedure
Flammability Tester Fire Propagation Test Apparatus 1
  • Six samples placed under 12mm thick calcium silicate cement
  • Key measurements:
    • Time for flame to arrive at each observation point
    • Flame spread distance in first 1.5 minutes
    • Total flame spread distance (10 minute test)
    • Maximum flame spread distance and time
Classification Standards
Classification Flame spread at 1.5 min (mm) Final flame spread (mm)
Class 1 165 (+25) 165 (+25)
Class 2 215 (+25) 455 (+25)
Class 3 265 (+25) 710 (+25)
Class 4 Exceeding Class 3 limits
Fire Propagation Testing
Flammability Tester Fire Propagation Test Apparatus 2
  • Measures temperature change via thermocouple sensor in sealed space during sample burning
  • Measurement intervals: Every 30s (0-3 min), every 1 min (4-10 min), every 2 min (12-20 min)
  • BS Class 0 standard: Class 1 material total index S ≤ 12; first sub-index ≤ 6
Environmental Requirements
  • Ground level, well ventilated area free of flammable, explosive, or corrosive gases/dust
  • No strong electromagnetic radiation sources nearby
  • Adequate maintenance space around equipment
  • Temperature: 5℃ ~ 30℃ (operating), 0℃ ~ 45℃ (non-operating)
  • Pressure: 86 ~ 106kpa
  • Power: AC380V / 50HZ (±10% voltage, ±1% frequency fluctuation)
  • User must provide appropriate capacity air/power switches for exclusive equipment use